Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
4.
Rev. Hosp. Clin. Univ. Chile ; 30(3): 218-222, 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1051237

ABSTRACT

Background: Echocardiography has now a pivotal role as a tool for hemodynamic monitoring, particularly in the critically ill. However, the ideal acoustic window for relevant measurements such as the velocity time integral are not always available. We propose to evaluate if angular correction of this variable is accurate in comparison with standard technique. Patients and methods: Adult patients were evaluated in the echocardiography unit during Juny 2017, having velocity time integral measured with angulation and standard technique, with convenience sampling. Analysis included difference, means and correlation between basal results and maximal angulation, in Stata 12. Results: 25 patients were included, mean velocity time integral was 23,01cm and with a mean angulation of 32,56º the integral was 24,27cm, with 5,5% difference, statistically significant, linear correlation had a 0,932 coefficient with R-square of 0,7897. Bland-Altman analysis revealed mean difference -1,256cm and agreement limits of -5,219 to 2,707. Discussion: In this study the result of the velocity time integral with angular correction had a good correlation and acceptable precision compared with non-angled measurements, which could allow its use when the acoustic window is sub-optimal, however, these findings should be replicated in critically ill patients. (AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Echocardiography/methods , Echocardiography/trends , Hemodynamic Monitoring/methods
5.
Int. braz. j. urol ; 41(2): 395-396, Mar-Apr/2015.
Article in English | LILACS | ID: lil-748311

ABSTRACT

Purpose Several surgical approaches have been used for varicocelectomy. We report single port varicocelectomy using SILS™ (Covidien, Norwalk, CT) multiple access port. Case The greade III varicocele patient was 23 years old and placed in supine position. About 2 cm vertical skin incision was made in a crease just lateral to the umbilicus and SILS™ port was placed with three 5-mm trocars. Incision to posterior peritoneum from the point 3 cm superior to the internal inguinal was made by needle holder with a broken 15th blade tip. The testicular vessels were exposed. The lymphatic vessels and testicular artery were identified and separated from the testicular vein with flexible laparoscopic instruments and conventional rigid instruments. Three testicular veins were clipped with hemoclips (EndoClip , Autosuture, Norwalk, CT). Posterior peritoneum was repaired with 4-0 vicryl with one side of 5 mm Hem-o-lok clip (Weck Research,Triangle Park, NC). Than the distal end of suture site was also closed with Hem-o-lok. Results The whole procedure was completed with no complication. The operative time was 85 minutes, and blood loss was minimal. The patient was discharged 2 days after the operation. Left scrotal pain and vein engorgement was disappeared. Conclusions Our single port varicocelectomy method is a safe and effective alternative to conventional method. This will provide minimally invasive surgical option for varicocele and we can expect more potential cosmetic benefit and less morbid. .


Subject(s)
Humans , Echocardiography/trends , Switzerland
6.
Arq. bras. cardiol ; 102(1): 97-103, 1/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-704054

ABSTRACT

A exequibilidade e o potencial para investigar o coração, sob o ponto de vista morfológico e hemodinâmico, vêm aumentando a aplicação da ecocardiografia na pesquisa. Além disso, o desenvolvimento de novas tecnologias, tais como a ecocardiografia tridimensional em tempo real e o speckle tracking, requerem validação por meio de estudos experimentais antes de serem instituídas no cenário clínico. O presente artigo objetiva fornecer informações acerca das particularidades do estudo ecocardiográfico nos mamíferos quadrúpedes, com vistas à pesquisa experimental.


The feasibility and potential for the morphological and hemodynamic investigation of the heart has been increasing the use of the echocardiography in the research setting. Additionally, the development of new technologies, like the real time 3D echocardiography and speckle tracking, demands validation throughout experimental studies before being instituted in the clinical setting. This paper aims to provide information concerning the particularities of the echocardiographic examination in quadruped mammals, targeting the experimental research.


Subject(s)
Animals , Echocardiography/methods , Echocardiography/trends , Models, Animal , Animal Experimentation , Heart Atria , Heart Ventricles , Medical Illustration
8.
Arq. bras. cardiol ; 100(4): 376-785, abr. 2013. ilus, tab
Article in Portuguese | LILACS | ID: lil-674193

ABSTRACT

FUNDAMENTO: O ecoDopplecardiograma (Eco) tem-se firmado como método não invasivo de excelente acurácia no rastreio de hipertensão portopulmonar (HPP) e pesquisa dos shunts intrapulmonares (SIP) na doença hepática crônica (DHC). Nesta última década, concretizou-se o Eco como de fundamental importância no diagnóstico da cardiomiopatia cirrótica (CMC). OBJETIVO: Realizar uma revisão sistemática envolvendo artigos relevantes sobre a temática: o Eco na DHC. MÉTODOS: Em novembro de 2011, realizou-se uma revisão sistemática a partir das bases de dados da Pubmed, LILACS e SciELO, sendo relatadas as características dos estudos selecionados. RESULTADOS: Foram encontrados 204 artigos a partir da busca de descritores e um termo livre, sendo 179 da Pubmed, 21 da LILACS e 01 da SciELO. Destes, foram selecionados 22 artigos para revisão sistemática, não sendo possível, pois, fazer uma meta-análise devido à heterogeneidade dos mesmos. CONCLUSÃO: O Eco deve fazer parte da estratificação da DHC para o rastreio de HPP, SIP e da CMC, já que a maioria das vezes, o diagnóstico dessas complicações ocorre nos pacientes na fila de transplante hepático.


BACKGROUND: Doppler echocardiography (Echo) is a non-invasive method of excellent accuracy to screen portopulmonary hypertension (PPH) and to assess intrapulmonary shunts (IPS) in chronic liver disease (CLD). In the past decade, Echo proved to play a fundamental role in the diagnosis of cirrhotic cardiomyopathy (CCM). OBJECTIVE: To perform a systematic review of relevant articles on the subject 'Echo in CLD'. METHODS: In November 2011, a systematic review was performed in the PubMed, LILACS and SciELO databases, and the characteristics of the studies selected were reported. RESULTS: The search based on descriptors and free terms obtained 204 articles (179 in Pubmed, 21 in LILACS, and 1 in SciELO). Of those 204 articles, 22 were selected for systematic review. A meta-analysis could not be performed because of the heterogeneity of the articles. CONCLUSIONS: Echo should be part of CLD stratification for screening PPH, IPS and CCM, because, most of the time, such complications are diagnosed only when patients are already waiting for a liver transplant.


Subject(s)
Female , Humans , Male , Cardiomyopathies , Liver Cirrhosis , Chronic Disease , Echocardiography/trends
9.
Rev. bras. ecocardiogr. imagem cardiovasc ; 23(3): 72-81, jul.-set. 2010. tab
Article in Portuguese | LILACS | ID: lil-556783

ABSTRACT

Atualmente os contrastes para ultrassom estão aprovados para várias situações da prática clínica. Estudos demonstram que são uma alternativa custo-efetiva no universo dos exames cardiológicos, reduzindo o número de testes complementares, especialmente, na investigação da doença arterial coronariana. Alguns softwares, aplicados em ecocardiografia, podem melhorar a visualização do contraste da borda endocárdica, opacificação da cavidade ventricular, ecocardiografia de estresse com contraste para análise de isquemia e viabilidade miocárdicas, perfusão miocárdica e abordagem do fluxo de reserva coronariano. Apesar dos questionamentos sobre a ecocardiografia contrastada, ocorridos nos últimos anos, suas indicações continuam sólidas em diretrizes internacionais e estudos multicêntricos demonstraram que o método é seguro e eficaz, além de enriquecer as informações diagnósticas e prognósticas dentro do campo cardiológico e radiológico. Nesta revisão, são discutidos todos esses pontos com maiores detalhes e com o objetivo de informar sobre as questões relevantes do contraste de microbolhas e como se encontra sua situação nos dias de hoje.


Subject(s)
Humans , Echocardiography, Stress , Echocardiography/economics , Echocardiography/trends , Ultrasonography/economics , Ultrasonography/trends
11.
Rev. SOCERJ ; 18(5): 457-463, set.-out. 2005. ilus, graf
Article in Portuguese | LILACS | ID: lil-428680

ABSTRACT

Objetivos:Avaliar a incidência e os preditores de morte súbita em uma coorte de pacientes com cardiopatia chagásica crônica e função sistólica preservada (FE maior 45 por cento).Métodos: Estudo prospectivo, longitudinal de uma coorte de 1053 pacientes com doença de Chagas, recrutados no período de 03/1990 a 03/2002 e acompanhados até 03/2003.todos foram submetidos a exame clínico, ECG, RX tórax e ECO na admissão.Na análise da incidência, foram descritas a incidência cumulativa e a incidência dencidade.Foram utilizaod o teste qui-quadrado para a comparação de variáveis categóricas e o teste t de Student para a comparação de médias entre 2 grupos. Resultados:Não houve qualquer caso de morte súbita entre os pacientes com ECG inicial normal.Nos 539 pacientes com ECG alterado, 377 aparesentavam FE maior 45 por cento e constituem a coorte de interesse


Subject(s)
Humans , Chagas Disease/complications , Chagas Disease/diagnosis , Chagas Disease/mortality , Death, Sudden/pathology , Death, Sudden/prevention & control , Arterial Pressure/physiology , Echocardiography/methods , Echocardiography/trends , Survival Analysis
12.
Rev. SOCERJ ; 18(2): 131-136, Mar-Abr. 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-407489

ABSTRACT

Objetivo: Avaliar a reprodutibilidade do ecocardiograma bidimensional(Eco2D)no diagnóstico de prolapso valvar mitral(PVM) em pacientes ambulatoriaisMétodos: Foram estudados prospectivamente, pelo Eco2D, 61 pacientes com suspeita clínica de PVM. Os exames foram realizados e gravados por quatro ecocardiografistas. Foram analisadas a presença e a localização de PVM, utilizando-se os critérios da American Society of Echocardiography, a presença, o tipo e o grau de incompetência mitral(IM), a redundância do septo interatrial(RSIA) e a degeneração mixomatosa dos folhetos mitrais(DM). Para a análise de concordância empregou-se o coeficiente Kappa(K). O teste qui-quadrado de McNemar foi utilizado para avaliar as diferenças entre as proporções de positividade dos itens avaliados. Foi considerado como significância estatística um nível de 5 por cento.Resultados: A concordância entre os examinadores pelo Eco2D para o diagnóstico de PVM foi de moderada/razoável a boa(K-0,412 a 0,640), sendo melhor quando estavam envolvidos ambosos folhetos(K0,566 a 0,814) e pior quando envolveu apenas o folheto anterior(K 0,157 a 0,740). Em relação ao tipo de IM, houve concordância muito boa(K 0,834 a 0,927). Em relação à DM, a concordância foi de razoável/moderada a boa (K 0,467 a 0,893) e para a presença de RSIA foi de superficial/razoável a boa(K 0,531 a 0,747), enquanto que para o grau de IM, houve concordância muito boa(K 0,834 a 0,927). Em relação à DM, a concordância foi de razoável/moderada a boa(K 0,467 a 0,893) e para a presença de RSIA foi de superficial/razoável a boa (K 0,258 a 0,818).Conclusão: Não se observou a concordância esperada entre os examinadores para a detecção de PVM, sugerindo a necessidade de novos critérios ecocardiográficos para o seu diagnóstico


Subject(s)
Humans , Male , Female , Middle Aged , Echocardiography/instrumentation , Echocardiography/trends , Echocardiography , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/physiopathology , Mitral Valve Prolapse/diagnosis , Mitral Valve Prolapse/physiopathology , Medical Examination/instrumentation
13.
Rev. bras. cir. cardiovasc ; 20(1): 63-68, Jan.-Mar. 2005. tab
Article in Portuguese | LILACS | ID: lil-413209

ABSTRACT

Objetivo: Avaliar a função ventricular diastólica do ventrículo esquerdo(VE)pelo ecocardiograma(ECO)uma e três semanas pós infarto agudo do miocárdio(IAM).Método: Utilizaram-se 19 ratas Wistar com peso médio de 209 gramas. Os animais foram distribuídos em: grupo A, controle(n=7)submetido a ECO e não infartado; grupo B, infartado(n=9), submetido a ECO após uma semana(grupo B1, n=9) e 3 semanas(grupo B3, n=8) do IAM. Três animais morreram no transoperatório e um após o primeiro ECO. Realizou-se anestesia com cetamina(50 mg/Kg/peso) e xilazina(10 mg/kg/peso)intraperitoneal, intubação e ventilação. O IAM foi induzido por ligadura da artéria descendente anterior após toracotomia esquerda. Avaliou-se a função cardíaca por ECO modelo 21275A HP Sonos 1500 com transdutor de 7,5/5,5 MHz e a função diastólica pelo Doppler transmitral com avaliação das ondas A e E, e volume atrial esquerdo(VAE). O IAM foi confirmado por análise histopatológica na terceira semana.Resultados: Não houve diferença significativa na velocidade das ondas E(A=62 cm/s, B1=65 cm/s, B3=69 cm/s) e onda(A=43 cm/s, B1=40 cm/s, B3=41 cm/s)entre os grupos. Observou-se aumento significativo no VAE grupo A vs B1 e grupo A vs B3(A= 0,05 ml vs B1=0,15 ml, p=0,04 e A vs B3=0,14 ml, p=0,01). Todos os animais apresentaram IAM na terceira semana.Conclusões: VAE parece ser útil para definição diastólica do VE pós-IAM. O VAE pode refletir aumento da pressão diastólica final do VE, secundário à disfunção sistólica e/ou diastólica


Subject(s)
Animals , Myocardial Contraction/physiology , Echocardiography/methods , Echocardiography/trends , Myocardial Infarction/diagnosis , Myocardial Infarction/physiopathology , Myocardial Infarction/rehabilitation , Counterpulsation
14.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 14(3): 429-440, Maio-Jun. 2004. ilus
Article in Portuguese | LILACS | ID: lil-407461

ABSTRACT

A identificação ecocardiográfica de cardiopatias em indivíduos com alterações genéticas e em familiares pode representar um avanço muito grande no manuseio dessas anomalias. Apresentamos de maneira resumida, as mais importantes doenças genéticas associadas a alterações cardiovasculares morfológicas e/ou funcionais, e suas correspondentes alterações ecocardiográficas. Em seguida discutimos sobre o valor do método no rastreamento de familiares com doenças genéticas


Subject(s)
Humans , Cardiomyopathy, Hypertrophic , Echocardiography/instrumentation , Echocardiography/trends , Echocardiography , Genetic Diseases, Inborn/physiopathology , Genetic Diseases, Inborn/genetics , Genetic Diseases, Inborn/pathology
15.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 10(5): 553-570, Setembro/Outubro 2000. tab
Article in Portuguese | LILACS, SES-SP, SESSP-IDPCPROD, SES-SP | ID: biblio-1066775

ABSTRACT

No contexto desta revisão sobre hipertensão pulmonar o presente artigo aborda o papel dos diferentes exames utilizados para avaliação anatômica e funcional da circulação pulmonar, com realce para os baseados em imageamento com diversos métodos.


Subject(s)
Angiography/methods , Angiography/trends , Echocardiography/methods , Echocardiography/trends , Magnetic Resonance Spectroscopy/methods , Hypertension, Pulmonary/diagnosis , Radiology/methods , Tomography, Emission-Computed/methods , Tomography, Emission-Computed/trends
SELECTION OF CITATIONS
SEARCH DETAIL